SIMCO has inspected, analyzed, tested, and found the causes of, and solutions to, a multitude of concrete deterioration problems affecting parking structures, from cracked foundations causing basement leaks to critical structural collapses. SIMCO’s analysis techniques are extensive and go far deeper than surface appearances. Information gleaned from analyses informs clients as to the condition of their concrete assets and what kind of performance they can expect from their infrastructure.
Comprehensive investigation and forensic analysis of the causes leading to major structural collapse
Multi-year repair plans, lifecycle cost analyses, monthly inspections and condition analyses for maintenance and repairs
Determine the current level of deterioration, and verify the effectiveness of repairs done following the last inspection in order to modify, as necessary, the maintenance and repair program
Condition assessment of multilevel parking structures and cost-optimal intervention strategy to extend the service life by 30 years
Residual service-life evaluation and durability planning of parking expansion